S6000 HPLC
S6000 HPLC

S6000 HPLC

Acchrom-tech, starting from the needs of users, analyzed the development history of liquid chromatography in the past 30 years, and based on the current advanced chromatography theory and new design i

S6000 HPLC System Advanced technology   Stable performance   Reliable for use   Flexible configuration

Based on the needs of users, Acchrom Tech analyzed the development process of liquid chromatography in the past 30 years, and built the S6000 HPLC system based on the self-developed patented technology and creative modular design ideas.


Pump System


Double ball series check valve

Pressure is more stable and the solvent is tolerated better.

HFM high-frequency mixing mode

 Improve the mixing accuracy of the mobile phase by increasing the proportional valve switching frequency.

The solvent is fully mixed without bigger mixer, which greatly reduces the system volume (<700ul) and improves the baseline noise caused by poor mixing.

High-speed feedback, real-time control & special cam curve design

Through the pressure monitoring of the system in real time, adjust the motor speed, equipped with the special curve cam drive, to ensure the stable flow, and effectively reduce the infusion pulsation. Stable flow pumping of 0.001-10.000 ml/min.


Sample Management System


Sample carryover can reach <0.003%

 Innovative inlet design to achieve long life seal and nearly zero dead volume.

Special flush flow path and rinse fluid to adequately flush the entire injection system.

Temperature-controlled automatic sampler

The temperature control uses the automatic injection sample detector temperature control module to realize the effective temperature control of 1℃ ~45. The temperature of the sampler can be accurately stabilized at the set value to ensure the stability of the temperature-sensitive samples.


Column Management System

creative high-capacity design

A 300-mm column can be placed

Built-in column switching valve or functional valve is optional

Heating / cooling mode:  Peltier

 Temperature setting range: 1~90℃

Heating / cooling bidirectional capability by powerful Peltier, temperature control is faster, more accurate, more stable.

Mobile Phase preheating function

The mobile phase is pre-heated before entering the column, which reduces the interference to the temperature environment in the column and ensures excellent peak shape symmetry and sharpness and reproducibility.


Rich Variety of Excellent Performance Detector

A variety of detectors are available

Provide complete detection techniques including UV, DAD, FLR, RI, ELS detectors.